For roofing companies
Quote from evidence, not from a ladder photo
You already climb, fly or scope every roof you price. AyeInspect turns those photos into a branded condition report your customer can actually understand — so the quote lands with proof attached.
- 3 free reports to start
- No subscription
- From £7.40 per report
- White-label
Homeowners say no to prices they cannot see the reason for. A report with the slipped ridge circled, graded and explained turns a cold quote into an obvious decision.
Tuned for what you look at
Your account runs the roofers detection profile, so the AI reports on the things your clients ask about.
- Slipped, cracked, missing and displaced tiles or slates
- Loose, missing or badly bedded ridge and hip tiles
- Lifted, split or poorly dressed lead flashing
- Chimney stack, pot and pointing defects
- Broken, sagging or misaligned guttering and downpipes
- Sagging, rafter spread and other signs of movement
What it does for the business
Higher quote acceptance
Send the report with the price. The customer sees the defect, the severity and the recommended remedial task written in roofing language.
Charge for the survey
Plenty of roofers now charge £80–£150 for a documented roof condition survey and credit it against the job if the work is booked.
Fewer wasted visits
Findings are graded, so you know before you load the van whether it is a half-day repair or a full strip and re-cover.
Protection after the job
Every finding keeps its original photo and date, so there is no argument later about what was already damaged.
Typical charge to your client
Typical charge to your client: £80–£150 per documented survey.
Four steps, about ten minutes
Step 1
Upload your photos
Any drone, phone or camera images.
Step 2
AI reviews each one
Defects circled, graded, described.
Step 3
You approve
Edit, reject or add anything by hand.
Step 4
Send in your name
Your logo, your colours, your domain.
See it in roofers' branding
Add your company name, colour and logo. Nothing is saved or uploaded — it all runs in your browser.
Make it yours
Like what you see?
Create your trade account and we'll carry this branding straight through. Your first 3 reports are on us.
Start free with 3 reportsYour Company
Roof condition report
Example Property, Glasgow G43
Prepared for Mr & Mrs Client
Summary of findings
The covering is generally sound for its age, but two issues need attention this season: a blocked gutter run that is already discharging down the rear wall, and eroded pointing to the chimney stack. Ridge bedding has failed along the front elevation and should be addressed within the next twelve months. The remaining findings are maintenance items that can be handled at the same visit.
1
Critical
2
High
3
Moderate
3
Low

Front elevation — main roof slope and ridge

Chimney stack — north elevation and hip junction

Rear right elevation — gutter run and downpipe head
- 1
Failed ridge bedding
Ridge & hip · HighMortar bedding along the ridge line has cracked and washed out in several places, leaving the ridge tiles held largely by their own weight. Moss growth in the open joints is holding moisture against the bedding.
Recommended: Re-bed the full ridge run in fresh mortar, or convert to a dry-fix ridge system for a longer-lived repair.
- 2
Displaced tile beside rooflight
Tiles / slates · ModerateA tile adjacent to the rooflight has lifted at its lower edge and is no longer seated on the batten, exposing the underlay to wind-driven rain.
Recommended: Re-seat and clip the tile, and check the rooflight flashing while access is set up.
- 3
Moss build-up on lower courses
Moss & debris · LowOrganic growth is established across the lower tile courses and at the eaves, retaining moisture on the covering and shedding debris into the gutter.
Recommended: Soft-brush the growth away and treat with a roof-safe biocide. Avoid pressure washing, which strips the tile surface.
- 4
Eroded pointing to stack
Chimney · HighMortar joints across the stack have weathered back and are open in several courses. Water entering the masonry here typically shows up internally as staining on the chimney breast.
Recommended: Rake out and re-point the stack, then re-seal the cap while scaffold or a tower is in place.
- 5
Lifted flashing at stack base
Flashing / lead · ModerateThe lead at the base of the stack is no longer dressed tight to the tile profile, leaving a gap at the upstand that will take water in driving rain.
Recommended: Re-dress the lead, re-wedge into the raked joint and point with lead sealant.
- 6
Moss to hip and ridge joints
Ridge & hip · LowMoss is establishing in the mortar joints along the hip and ridge run. Not urgent, but it accelerates bedding failure if left for several winters.
Recommended: Clear growth from the joints and monitor at the next inspection.
- 7
Blocked gutter run above downpipe
Guttering · CriticalThe gutter is silted with moss and debris to roughly half its depth immediately above the downpipe outlet. Standing water is already visible along the channel, and overflow at this point runs directly down the wall below.
Recommended: Clear the full run and the downpipe, flush with water to confirm flow, and check the wall below for existing damp penetration.
- 8
Bracket pulling from fascia
Guttering · ModerateOne gutter bracket has worked loose and the section has dropped slightly, reversing the fall over about a metre of the run.
Recommended: Re-fix the bracket into sound timber and re-level the section to restore the fall.
- 9
Chipped tile at verge
Tiles / slates · LowA tile at the verge has a chipped lower corner. Cosmetic at present with no exposed underlay behind it.
Recommended: No action required now; replace if the chip progresses into a crack.
Example property imagery: Top-down overview — example property, Glasgow G43. Findings shown are from a real survey format; the branding is yours.